Anywhere from 1/4 to 1/2 page comes out very faded (ltr size second side of 2 sided mostly). Restrung all wires and replaced trans-sep corona assm (new). Still has the problem. About 1 out of every 5 copies has it.
Customer ran 2000 2 sided ltr-r with no problems today so it only happens on ltr size (weird?).
It started happening after I replaced the dc controller for an e-025 code (blown fuse). I installed a repaired board from Hytec, re-input door specs and made sure pot ctrl was on.
Any suggestions?
ir5570Sample.pdf
ir5570Sample.pdf
Customer ran 2000 2 sided ltr-r with no problems today so it only happens on ltr size (weird?).
It started happening after I replaced the dc controller for an e-025 code (blown fuse). I installed a repaired board from Hytec, re-input door specs and made sure pot ctrl was on.
Any suggestions?
ir5570Sample.pdf
ir5570Sample.pdf